livechat
livechat

contact us

Use the form on the right to contact us.

You can edit the text in this area, and change where the contact form on the right submits to, by entering edit mode using the modes on the bottom right.

300 Liberty Avenue
East New York, NY, 11207
United States

(800) 347-3494

HeartStart FR2+ AED w/ ECG Display & TSO FAA-Compliant Battery (Refurbished)

Defibrillators

HeartStart FR2+ AED w/ ECG Display & TSO FAA-Compliant Battery (Refurbished)

PHI861458-A01-ER.jpg
PHI861458-A01-ER.jpg

HeartStart FR2+ AED w/ ECG Display & TSO FAA-Compliant Battery (Refurbished)

0.00

PHI861458-A01

For professional and lay responder alike, HeartStart FR2+ was designed for fast, efficient operation.

SMART CPR - Patient specific treatment
The HeartStart SMART CPR evaluates key characteristics of the presenting ventricular fibrillation and determines the initial therapy: shock first, or CPR first quickly followed by a shock.

Easy hand-off - Allows a continuity of patient care
Advanced life support (ALS) trained professionals can easily switch the HeartStart FR2+ to manual mode, giving them more decision-making control. An ECG display is also available for critical review.

SMART Biphasic therapy - Safely delivers shock
Philips SMART Biphasic therapy uses a unique combination of high current - to increase effectiveness, and a low energy dose - to decrease side effects that are harmful to a fragile heart.

Built-in self test - Ready when needed
Your HeartStart FR2+ goes through a 120-point test before it leaves the factory. On the job, it conducts self tests daily, not just weekly. It performs over 80 different tests, including pads integrity with visual & attention-getting audible alerts.

Quick Shock feature - Reduce chest compressions
CPR is even more vital to survival than previously realized. Rapidly delivering a shock after chest compressions is critical. The HeartStart FR2+’s Quick Shock feature reduces the time between hands-off and shock delivery.

Simple to use - Clear, calm voice commands
Operation of the HeartStart FR2+ is guided by clear, streamlined, confident, and concise, voice commands: ideal for responders who are trained, drilled, and ready to save a life.

Includes:

  • 1 FR2+ AED
  • 1 Set of instructions for use
  • 1 Standard battery, FAA Compliant
  • 2 Pair defibrillator
  • 1 Quick Reference Guide

Specifications:

Waveform:
Truncated exponential biphasic. Waveform parametersadjusted as a function of patient impedance

Therapy:

  • Adult defibrillation peak current: 32A (150J nominal) into a 50 ohm load; Pediatric defibrillation (utilizes infant/child pads): 19A (50J nominal) into a 50 ohm load
  • Charge Time from Shock Advised: Typically less than 10 seconds
  • Charge Time in Manual Mode: Typically less than 5 seconds
  • Shock-to-Shock Cycle Time: Typically less than 15 seconds (including analysis time) in automated mode

Protocol:

  • Text and voice prompts guide user through protocol. Follows pre-configured settings. Can be modified with the training and administration pack (PHIM3864A)
  • Shock Delivery: Via defibrillator pads placed in anterior-anterior (lead II) position for adult defibrillation and anterior-posterior for infant/child defibrillation
  • Controls: On/Off, Shock, screen contrast/option buttons
  • Indicators: LCD screen, beeper, audio speakers, status indicator. Shock button connector socket LED
  • Advanced Mode: Configurable protocol

ECG Display:

  • Screen: High-resolution LCD with bright back-light
  • Screen Dimensions: 2.8 inches wide x 2.3 inches high (7.0 cm x 5.8 cm)
  • Display Range: Differential: ±2 mV full scale (nominal)
  • Sweep Speed: 23 mm/second (nominal)
  • Frequency Response: 1 Hz to 20 Hz (-3dB) (nominal)
  • Sensitivity: 1.16 cm/mV (nominal)
  • Heart Rate: 30 to 300 beats per minute updated each analysis period during monitoring
  • Monitored Lead: Anterior-anterior (lead II) placement with adult defibrillation pads or ECG Assessment Module (PHIM3860A) only

Patient Analysis System:

  • Patient Analysis: Per protocol, evaluates patient ECG and signal quality to determine if rhythm is shockable, and evaluates connection impedance for proper defibrillation pad contact
  • Sensitivity/Specificity: Meets AAMI DF-80 guidelines and AHA recommendationsfor adult defibrillation (Circulation 1997;95:1677-1682)

SMART CPR (configurable):

  • Enables support of an automated or user-initiated CPR interval prior to defibrillation shockable rhythm. Once the decision is made, FR2+ provides the responder with the appropriate prompts.
  • SMART AUTO 1: advises CPR for patients with a presenting rhythm typical of very long-duration cardiac arrest.
  • SMART AUTO 2: advises CPR for an expanded group of patients inclusive of those in Auto 1, having a rhythm typical of long duration cardiac arrest
  • USER: user-initiated CPR Pause interval. Supports a protocol under which the responder decides whether to perform CPR first. A Pause-for-CPR button is enabled, and can be pressed at the responder’s discretion.
  • The AUTO 1 and AUTO 2 settings automate the decision of whether to provide CPR first or deliver a shock first based on the amplitude and frequency of the presenting
  • Quick Shock Able to deliver a shock in typically less than 10 seconds after the end of a CPR interval.

Infant/Child Defibrillation Pads (PHIM3870A):

  • Patient: Under 8 years or 55 lbs / 25 kg
  • Defibrillator Compatibility FR2-series: (FR2 and FR2+) automated external defibrillator only
  • Configuration: 1 set per package
  • How Supplied: Disposable self-adhesive pads with cable and connector
  • Therapy Delivered: Reduces defibrillator shock peak current to 19A (50 Joules nominal) into a 50 ohm load
  • Sureface Area: Meets AAMI DF-80 guidelines
  • Cable Length: Approximately 48 lbs / 122 cm

Medical Control/Recording Features:

  • Standard Event Review: Elapsed time and number of shocks are displayed on screen
  • Enhanced Event Review: Optional data card (PHIM3854A) expands the above on-screen event review capabilities. Review chronological events in detail including ECG 8 hours of event and ECG recording or one hour if voice recording is activated

FR2 Series Standard Battery (PHIM3863A):

  • Type: 12 VDC 4.2 Ah lithium manganese. Disposable, recyclable, long-life, primary cells
  • Capacity: Minimum 300 shocks or 12 hours of operating time (EN 60601-2-4:2003)
  • Install-by Date Battery is labeled with an install-by date at least 5 years from date of manufacture
  • Standby Life: Defines how long the battery will power the AED in standby operation within the standby temperature range (one battery insert test and no uses). 4 years minimum when battery is installed by the install-by date (5 years typical)

Environmental/Physical Requirements:

  • Sealing: Meets IEC529 class IP54 with battery and data card tray installed
  • Temperature : Operating: 32º - 122º F / 0º - 50º C; Standby: 32º - 109º F / 0º - 43º C - Standby applies to AED with battery installed and stored with defibrillation pads
  • Humidity: Operating: 0% to 95% relative humidity (non-condensing); Standby: 0% to 75% relative humidity (non-condensing)
  • Altitude: -500 to 15,000 feet per MIL-STD-810E 500.3 Procedure II
  • Aircraft: Method: RTCA/DO-160D: 1997 Section 21 (Category M - Charging)
  • Shock/Drop Abuse Tolerance: 1 meter any edge, corner or surface. MIL-STD-810E 516.4 Procedure IV
  • Vibration: MIL-STD-810E 514.4-17
  • EMI: Requirements: Tested to EN60601-1-2 Limits; Radiated: Method EN55011: 1998 Group 1 Level B; Immunity: Method EN61000-4-3:1998 Level 2

Automated and User-activated Self-tests:

  • Automatic Self-tests: Tests internal circuitry, waveform delivery system, and battery capacity. Verifies calibration of key circuits monthly
  • Automatic Self-test Frequency: Daily when stored within operating environmental conditions
  • Status Indication: Dynamic visual and audible indication of self-test results. Indicates device readiness
  • Battery Insertion Test: Upon battery insertion, extensive automatic self-tests and user interactive tests check device readiness. Verifies calibration of key circuits
  • Automatic Standby Temperature Monitoring: Instrument automatically monitors temperature and warns user if device is stored outside of standby temperature range

Dimensions:

  • Height: 8.6" / 21.8 cm.
  • Width: 8.6" / 21.8 cm.
  • Depth: 2.6" / 6.6 cm.

Weight:

  • With battery: 4.7 lbs / 2.1 kg.
  • Without battery: 3.9 lbs / 1.8 kg
Add To Cart